---
agent:
  instructions: "Use this search API to find relevant content across this site with keywords or natural-language queries, instead of crawling individual pages. Results are returned in Markdown."
  endpoint: "https://calibrationservicecompanies.com/.well-known/search?q={query}"
  method: "GET"
  documentation: "https://developers.cloudflare.com/ai-search/how-to/search-for-agents/"
title: "Onsite temperature calibration | Calibration Service Companies"
description: "Which labs calibrate temperature instruments onsite?"
image: "https://calibrationservicecompanies.com/og.jpg"
url: "https://calibrationservicecompanies.com/onsite-temperature-calibration/"
last_updated: "2026-11-28"
---

> Site index for agents: https://calibrationservicecompanies.com/llms.txt

# Onsite temperature calibration

[25 labs](https://calibrationservicecompanies.com/onsite-temperature-calibration/#shortlist) in the register have a temperature interval explicitly marked for field calibration in the linked scope. Use those entries to plan a visit, then give the lab your worksite conditions and required uncertainty for the job.

## Published scope examples

| Lab | Scope item | Range | CMC | Scope |
| --- | --- | --- | --- | --- |
| [Applied Technical Services · Bartlett, TN](https://calibrationservicecompanies.com/applied-technical-services-bartlett-tn-1888-05/) | Temperature – Measure3 | [(-80 to 420) C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=4CD6FEBC-1011-4004-9385-2C63EE304531&documentPID=B2C8E63D-916F-41AF-91E4-EB7D1A57FAAC#page=17) | [0.056 C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=4CD6FEBC-1011-4004-9385-2C63EE304531&documentPID=B2C8E63D-916F-41AF-91E4-EB7D1A57FAAC#page=17) | [PDF p. 17](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=4CD6FEBC-1011-4004-9385-2C63EE304531&documentPID=B2C8E63D-916F-41AF-91E4-EB7D1A57FAAC#page=17) |
| [Applied Technical Services · Greer, SC](https://calibrationservicecompanies.com/applied-technical-services-greer-sc-1888-09/) | Temperature – Measure3 | [(-80 to 420) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=AD73283B-D685-4DA9-9524-F33F71A40DC9&documentPID=04B98169-CF38-4AF8-9F2B-2ECB03805158#page=16) | [0.056 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=AD73283B-D685-4DA9-9524-F33F71A40DC9&documentPID=04B98169-CF38-4AF8-9F2B-2ECB03805158#page=16) | [PDF p. 16](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=AD73283B-D685-4DA9-9524-F33F71A40DC9&documentPID=04B98169-CF38-4AF8-9F2B-2ECB03805158#page=16) |
| [Applied Technical Services · Marietta, GA](https://calibrationservicecompanies.com/applied-technical-services-marietta-ga-1888-03/) | Temperature – Measure3 | [(-196 to 650) C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=0DE6F012-C334-4885-8A9C-4E1E890B3FAB&documentPID=A339866F-BA6A-417E-9F40-C6A76EF86449#page=45) | [0.025 C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=0DE6F012-C334-4885-8A9C-4E1E890B3FAB&documentPID=A339866F-BA6A-417E-9F40-C6A76EF86449#page=45) | [PDF p. 45](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=0DE6F012-C334-4885-8A9C-4E1E890B3FAB&documentPID=A339866F-BA6A-417E-9F40-C6A76EF86449#page=45) |
| [Applied Technical Services · Sacramento, CA](https://calibrationservicecompanies.com/applied-technical-services-sacramento-ca-7337-01/) | Temperature – Measure3 | [(-40 to 0) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=7E06E48F-848E-4E56-AAB4-B3DF3E336284&documentPID=1E5D32AA-33B5-45A4-BA17-4C552F24D940#page=16) | [1.2 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=7E06E48F-848E-4E56-AAB4-B3DF3E336284&documentPID=1E5D32AA-33B5-45A4-BA17-4C552F24D940#page=16) | [PDF p. 16](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=7E06E48F-848E-4E56-AAB4-B3DF3E336284&documentPID=1E5D32AA-33B5-45A4-BA17-4C552F24D940#page=16) |
| [Applied Technical Services · Tempe, AZ](https://calibrationservicecompanies.com/applied-technical-services-tempe-az-1888-08/) | Temperature – Measure3 | [(-195 to 660) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=1E97FA96-BD67-4587-8ADA-087EFA9F5B34&documentPID=14577486-0FE8-4ED1-B8F1-E57B37F1FBC0#page=17) | [0.056 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=1E97FA96-BD67-4587-8ADA-087EFA9F5B34&documentPID=14577486-0FE8-4ED1-B8F1-E57B37F1FBC0#page=17) | [PDF p. 17](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=1E97FA96-BD67-4587-8ADA-087EFA9F5B34&documentPID=14577486-0FE8-4ED1-B8F1-E57B37F1FBC0#page=17) |
| [Calibration Solutions · Pflugerville, TX](https://calibrationservicecompanies.com/calibration-solutions-pflugerville-tx-3752-01/) | Temperature –Measure3 | [(-100 to 1000) °F](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=D1E913DD-355D-40E6-82F0-EEF646FCA5CC&documentPID=B4FF621C-B5AC-40D2-BFF3-07575E3A09B7#page=4) | [2.5 + 5.5 x 10-4T F](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=D1E913DD-355D-40E6-82F0-EEF646FCA5CC&documentPID=B4FF621C-B5AC-40D2-BFF3-07575E3A09B7#page=4) | [PDF p. 4](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=D1E913DD-355D-40E6-82F0-EEF646FCA5CC&documentPID=B4FF621C-B5AC-40D2-BFF3-07575E3A09B7#page=4) |
| [Grand Rapids Metrology · Grand Rapids, MI](https://calibrationservicecompanies.com/grand-rapids-metrology-grand-rapids-mi-1489-01/) | Temperature – Measure3 | [(-200 to 0) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=DFB07005-F266-497D-8D6C-95F7AE73FBD2&documentPID=810EFF85-96B0-4B03-8D02-ABEF7FA43CF5#page=14) | [3.6 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=DFB07005-F266-497D-8D6C-95F7AE73FBD2&documentPID=810EFF85-96B0-4B03-8D02-ABEF7FA43CF5#page=14) | [PDF p. 14](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=DFB07005-F266-497D-8D6C-95F7AE73FBD2&documentPID=810EFF85-96B0-4B03-8D02-ABEF7FA43CF5#page=14) |
| [JJ Calibrations · Portland, OR](https://calibrationservicecompanies.com/jj-calibrations-portland-or-723-01/) | Temperature – Measure3 | [(-100 to 660) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=258C02F1-7991-4465-AFB1-710811B09225&documentPID=39680DD7-9DF3-48C1-9AD7-172D3F1F6FD6#page=13) | [0.005 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=258C02F1-7991-4465-AFB1-710811B09225&documentPID=39680DD7-9DF3-48C1-9AD7-172D3F1F6FD6#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=258C02F1-7991-4465-AFB1-710811B09225&documentPID=39680DD7-9DF3-48C1-9AD7-172D3F1F6FD6#page=13) |
| [National Calibration · Albuquerque, NM](https://calibrationservicecompanies.com/national-calibration-albuquerque-nm-1892-02/) | Thermometers3 | [(-20 to 100) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=33538393-AA92-45A2-A3AA-4E137AD20B74&documentPID=9A1011CA-06C2-45BD-81CE-C72BEF79EBE8#page=13) | [0.059 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=33538393-AA92-45A2-A3AA-4E137AD20B74&documentPID=9A1011CA-06C2-45BD-81CE-C72BEF79EBE8#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=33538393-AA92-45A2-A3AA-4E137AD20B74&documentPID=9A1011CA-06C2-45BD-81CE-C72BEF79EBE8#page=13) |
| [National Calibration · Scottsdale, AZ](https://calibrationservicecompanies.com/national-calibration-scottsdale-az-1892-01/) | Temperature – Measure3 | [(-80 to -20) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=7512ED30-1475-461C-9085-D4A86FE65DFB&documentPID=06BC6AFE-9DA9-447A-91CF-61559470B8CB#page=25) | [0.012 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=7512ED30-1475-461C-9085-D4A86FE65DFB&documentPID=06BC6AFE-9DA9-447A-91CF-61559470B8CB#page=25) | [PDF p. 25](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=7512ED30-1475-461C-9085-D4A86FE65DFB&documentPID=06BC6AFE-9DA9-447A-91CF-61559470B8CB#page=25) |
| [Northstar Calibration · Owatonna, MN](https://calibrationservicecompanies.com/northstar-calibration-owatonna-mn-462-02/) | Infrared Thermometers3 | [(85 to 750) °F](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=357743EE-AB25-4ECD-9A9C-204F3C35A832&documentPID=61385EE6-4FDB-498B-ADB6-B16D9A8A9200#page=19) | [(0.65 + 0.0016T) °F](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=357743EE-AB25-4ECD-9A9C-204F3C35A832&documentPID=61385EE6-4FDB-498B-ADB6-B16D9A8A9200#page=19) | [PDF p. 19](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=357743EE-AB25-4ECD-9A9C-204F3C35A832&documentPID=61385EE6-4FDB-498B-ADB6-B16D9A8A9200#page=19) |
| [PharmaMatrix, LLC dba Applied Calibration Services · Wilson, NC](https://calibrationservicecompanies.com/pharmamatrix-llc-dba-applied-calibration-services-wilson-nc-3374-01/) | Temperature – Measure3 | [(-80 to 0) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=046A14B4-7265-43D8-86EB-D736278B4BD3&documentPID=EC2D0351-0E1F-4EAD-8A3F-EE07F9AB6E00#page=9) | [0.046 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=046A14B4-7265-43D8-86EB-D736278B4BD3&documentPID=EC2D0351-0E1F-4EAD-8A3F-EE07F9AB6E00#page=9) | [PDF p. 9](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=046A14B4-7265-43D8-86EB-D736278B4BD3&documentPID=EC2D0351-0E1F-4EAD-8A3F-EE07F9AB6E00#page=9) |
| [Quality Calibration Service · New Berlin, WI](https://calibrationservicecompanies.com/quality-calibration-service-new-berlin-wi-462-01/) | Infrared Thermometers3 | [(-15 to 100) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=42693258-4A16-402A-B64A-40DA7AAF0371&documentPID=A742EB61-9181-4BCF-BA03-DF9240D352C0#page=18) | [0.74 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=42693258-4A16-402A-B64A-40DA7AAF0371&documentPID=A742EB61-9181-4BCF-BA03-DF9240D352C0#page=18) | [PDF p. 18](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=42693258-4A16-402A-B64A-40DA7AAF0371&documentPID=A742EB61-9181-4BCF-BA03-DF9240D352C0#page=18) |
| [SIMCO · Allentown, PA](https://calibrationservicecompanies.com/simco-allentown-pa-1395-09/) | Temperature – Measure3, | [(-50 to 150) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=E97B009D-1676-4B1A-988B-AFA0D0DC4F92&documentPID=D03C2D4C-855F-479D-9E01-D81CCD985805#page=21) | [0.059 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=E97B009D-1676-4B1A-988B-AFA0D0DC4F92&documentPID=D03C2D4C-855F-479D-9E01-D81CCD985805#page=21) | [PDF p. 21](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=E97B009D-1676-4B1A-988B-AFA0D0DC4F92&documentPID=D03C2D4C-855F-479D-9E01-D81CCD985805#page=21) |
| [SIMCO · Bloomington, MN](https://calibrationservicecompanies.com/simco-bloomington-mn-1395-14/) | Temperature – Measure3 | [(-196 to 420) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=755500DC-3E63-48F3-BCC3-DC58FBE4273E&documentPID=2B07349F-95E7-4BCC-BB14-98369B5A6B1E#page=13) | [0.068 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=755500DC-3E63-48F3-BCC3-DC58FBE4273E&documentPID=2B07349F-95E7-4BCC-BB14-98369B5A6B1E#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=755500DC-3E63-48F3-BCC3-DC58FBE4273E&documentPID=2B07349F-95E7-4BCC-BB14-98369B5A6B1E#page=13) |
| [SIMCO · Panorama City, CA](https://calibrationservicecompanies.com/simco-panorama-city-ca-1395-05/) | Temperature – Measure3 | [(-196 to 0) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=B344B414-4AC8-48F1-B0E6-E603C10E1C3C&documentPID=9B0F9E34-B113-4D7D-81A1-F0BBB47FA9D3#page=24) | [0.018 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=B344B414-4AC8-48F1-B0E6-E603C10E1C3C&documentPID=9B0F9E34-B113-4D7D-81A1-F0BBB47FA9D3#page=24) | [PDF p. 24](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=B344B414-4AC8-48F1-B0E6-E603C10E1C3C&documentPID=9B0F9E34-B113-4D7D-81A1-F0BBB47FA9D3#page=24) |
| [SIMCO · Santa Clara, CA](https://calibrationservicecompanies.com/simco-santa-clara-ca-1395-17/) | Temperature – Measure3 | [(-40 to 140) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=8CEE2ED1-20C6-49D1-B471-3DA57E006748&documentPID=44299B52-53EC-48C1-BB8A-1EDA025F8DEA#page=16) | [0.028 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=8CEE2ED1-20C6-49D1-B471-3DA57E006748&documentPID=44299B52-53EC-48C1-BB8A-1EDA025F8DEA#page=16) | [PDF p. 16](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=8CEE2ED1-20C6-49D1-B471-3DA57E006748&documentPID=44299B52-53EC-48C1-BB8A-1EDA025F8DEA#page=16) |
| [SIMCO · Springboro, OH](https://calibrationservicecompanies.com/simco-springboro-oh-1395-02/) | Temperature – Measure3 | [(-196 to 420) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=448285C5-1558-4770-96DD-BA1DEF9F6A4F&documentPID=A1C04DE6-4C4E-4A01-B892-322C8DACA3BA#page=13) | [0.004 % + 0.037 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=448285C5-1558-4770-96DD-BA1DEF9F6A4F&documentPID=A1C04DE6-4C4E-4A01-B892-322C8DACA3BA#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=448285C5-1558-4770-96DD-BA1DEF9F6A4F&documentPID=A1C04DE6-4C4E-4A01-B892-322C8DACA3BA#page=13) |
| [SIMCO · Springboro, OH](https://calibrationservicecompanies.com/simco-springboro-oh-1395-02/) | Infrared Thermometers3 | [(25 to 100) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=448285C5-1558-4770-96DD-BA1DEF9F6A4F&documentPID=A1C04DE6-4C4E-4A01-B892-322C8DACA3BA#page=13) | [0.68 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=448285C5-1558-4770-96DD-BA1DEF9F6A4F&documentPID=A1C04DE6-4C4E-4A01-B892-322C8DACA3BA#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=448285C5-1558-4770-96DD-BA1DEF9F6A4F&documentPID=A1C04DE6-4C4E-4A01-B892-322C8DACA3BA#page=13) |
| [Trescal · Arlington Heights, IL](https://calibrationservicecompanies.com/trescal-arlington-heights-il-1022-03/) | Temperature – Measure3 | [(-196 to 420) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=29B37D4F-9C75-402C-8C0F-827BDF0B7AEE&documentPID=2A56D881-322F-46EC-8A88-F3906F422332#page=31) | [0.043 °C + 0.000 059 x](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=29B37D4F-9C75-402C-8C0F-827BDF0B7AEE&documentPID=2A56D881-322F-46EC-8A88-F3906F422332#page=31) | [PDF p. 31](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=29B37D4F-9C75-402C-8C0F-827BDF0B7AEE&documentPID=2A56D881-322F-46EC-8A88-F3906F422332#page=31) |
| [Trescal · Cornelius, NC](https://calibrationservicecompanies.com/trescal-cornelius-nc-1877-01/) | Temperature – Measure3 | [(-196 to 0) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=EC747AFB-56E9-4669-8C63-103605C6A71A&documentPID=B0455C9F-3365-4668-8B99-3719A6076712#page=37) | [0.0055 °C - 0.000 004 x Additel 286 reference](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=EC747AFB-56E9-4669-8C63-103605C6A71A&documentPID=B0455C9F-3365-4668-8B99-3719A6076712#page=37) | [PDF p. 37](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=EC747AFB-56E9-4669-8C63-103605C6A71A&documentPID=B0455C9F-3365-4668-8B99-3719A6076712#page=37) |
| [Trescal · Lansdale, PA](https://calibrationservicecompanies.com/trescal-lansdale-pa-2551-01/) | Temperature – Measure3 | [(-196 to 660) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=220E5747-B040-42C8-8DA8-EB185BA447B6&documentPID=9FC9F53C-5ECD-4E71-9990-F23190625963#page=13) | [0.0025 °C + 0.000 021](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=220E5747-B040-42C8-8DA8-EB185BA447B6&documentPID=9FC9F53C-5ECD-4E71-9990-F23190625963#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=220E5747-B040-42C8-8DA8-EB185BA447B6&documentPID=9FC9F53C-5ECD-4E71-9990-F23190625963#page=13) |
| [Trescal · Milwaukee, WI](https://calibrationservicecompanies.com/trescal-milwaukee-wi-1078-01/) | Thermometers3 | [(35 to 500) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=C345AD56-0EFF-4419-8820-2D55E606BF70&documentPID=D943D747-4062-4490-BA22-B9681037BD84#page=60) | [0.47 °C + 0.0047 °C/°C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=C345AD56-0EFF-4419-8820-2D55E606BF70&documentPID=D943D747-4062-4490-BA22-B9681037BD84#page=60) | [PDF p. 60](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=C345AD56-0EFF-4419-8820-2D55E606BF70&documentPID=D943D747-4062-4490-BA22-B9681037BD84#page=60) |
| [Trescal · Providence Forge, VA](https://calibrationservicecompanies.com/trescal-providence-forge-va-1486-02/) | Temperature – Measure3 | [(-70 to 180) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=5AE82B36-4445-4C39-8772-5C396600748B&documentPID=F76C61A1-0FDA-4D6E-B84F-77F42C4A04CF#page=13) | [0.23 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=5AE82B36-4445-4C39-8772-5C396600748B&documentPID=F76C61A1-0FDA-4D6E-B84F-77F42C4A04CF#page=13) | [PDF p. 13](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=5AE82B36-4445-4C39-8772-5C396600748B&documentPID=F76C61A1-0FDA-4D6E-B84F-77F42C4A04CF#page=13) |
| [Trescal · San Jose, CA](https://calibrationservicecompanies.com/trescal-san-jose-ca-1797-01/) | Temperature – Measure3 | [(-200 to 420) C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=2C8BCAAC-4D41-4F4E-9D46-B3472F3B9DE8&documentPID=E5F0B8AE-78B9-4D4A-AC0E-92458D741C93#page=56) | [0.074 C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=2C8BCAAC-4D41-4F4E-9D46-B3472F3B9DE8&documentPID=E5F0B8AE-78B9-4D4A-AC0E-92458D741C93#page=56) | [PDF p. 56](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=2C8BCAAC-4D41-4F4E-9D46-B3472F3B9DE8&documentPID=E5F0B8AE-78B9-4D4A-AC0E-92458D741C93#page=56) |
| [usCalibration · Irvine, CA](https://calibrationservicecompanies.com/uscalibration-irvine-ca-2092-01/) | Temperature – Measure3 | [(-200 to 0) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=66C3BEBC-0E41-4D6D-BA45-213D4FD79C16&documentPID=7AEA06DB-64CD-441A-BD5F-836BDA1E0EEA#page=19) | [0.065 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=66C3BEBC-0E41-4D6D-BA45-213D4FD79C16&documentPID=7AEA06DB-64CD-441A-BD5F-836BDA1E0EEA#page=19) | [PDF p. 19](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=66C3BEBC-0E41-4D6D-BA45-213D4FD79C16&documentPID=7AEA06DB-64CD-441A-BD5F-836BDA1E0EEA#page=19) |
| [usCalibration · Irvine, CA](https://calibrationservicecompanies.com/uscalibration-irvine-ca-2092-01/) | Infrared Thermometers3 | [(32 to 216) °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=66C3BEBC-0E41-4D6D-BA45-213D4FD79C16&documentPID=7AEA06DB-64CD-441A-BD5F-836BDA1E0EEA#page=19) | [0.25 % + 0.92 °C](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=66C3BEBC-0E41-4D6D-BA45-213D4FD79C16&documentPID=7AEA06DB-64CD-441A-BD5F-836BDA1E0EEA#page=19) | [PDF p. 19](https://customer.a2la.org/index.cfm?event=directory.getDocument&accreditationPID=66C3BEBC-0E41-4D6D-BA45-213D4FD79C16&documentPID=7AEA06DB-64CD-441A-BD5F-836BDA1E0EEA#page=19) |

## Lab shortlist

[Source data](https://calibrationservicecompanies.com/data.json)

*   [Applied Technical Services · Bartlett, TN](https://calibrationservicecompanies.com/applied-technical-services-bartlett-tn-1888-05/)
*   [Applied Technical Services · Greer, SC](https://calibrationservicecompanies.com/applied-technical-services-greer-sc-1888-09/)
*   [Applied Technical Services · Marietta, GA](https://calibrationservicecompanies.com/applied-technical-services-marietta-ga-1888-03/)
*   [Applied Technical Services · Sacramento, CA](https://calibrationservicecompanies.com/applied-technical-services-sacramento-ca-7337-01/)
*   [Applied Technical Services · Tempe, AZ](https://calibrationservicecompanies.com/applied-technical-services-tempe-az-1888-08/)
*   [Calibration Solutions · Pflugerville, TX](https://calibrationservicecompanies.com/calibration-solutions-pflugerville-tx-3752-01/)
*   [Grand Rapids Metrology · Grand Rapids, MI](https://calibrationservicecompanies.com/grand-rapids-metrology-grand-rapids-mi-1489-01/)
*   [JJ Calibrations · Portland, OR](https://calibrationservicecompanies.com/jj-calibrations-portland-or-723-01/)
*   [National Calibration · Albuquerque, NM](https://calibrationservicecompanies.com/national-calibration-albuquerque-nm-1892-02/)
*   [National Calibration · Scottsdale, AZ](https://calibrationservicecompanies.com/national-calibration-scottsdale-az-1892-01/)
*   [Northstar Calibration · Owatonna, MN](https://calibrationservicecompanies.com/northstar-calibration-owatonna-mn-462-02/)
*   [PharmaMatrix, LLC dba Applied Calibration Services · Wilson, NC](https://calibrationservicecompanies.com/pharmamatrix-llc-dba-applied-calibration-services-wilson-nc-3374-01/)
*   [Quality Calibration Service · New Berlin, WI](https://calibrationservicecompanies.com/quality-calibration-service-new-berlin-wi-462-01/)
*   [SIMCO · Allentown, PA](https://calibrationservicecompanies.com/simco-allentown-pa-1395-09/)
*   [SIMCO · Bloomington, MN](https://calibrationservicecompanies.com/simco-bloomington-mn-1395-14/)
*   [SIMCO · Panorama City, CA](https://calibrationservicecompanies.com/simco-panorama-city-ca-1395-05/)
*   [SIMCO · Santa Clara, CA](https://calibrationservicecompanies.com/simco-santa-clara-ca-1395-17/)
*   [SIMCO · Springboro, OH](https://calibrationservicecompanies.com/simco-springboro-oh-1395-02/)
*   [Trescal · Arlington Heights, IL](https://calibrationservicecompanies.com/trescal-arlington-heights-il-1022-03/)
*   [Trescal · Cornelius, NC](https://calibrationservicecompanies.com/trescal-cornelius-nc-1877-01/)
*   [Trescal · Lansdale, PA](https://calibrationservicecompanies.com/trescal-lansdale-pa-2551-01/)
*   [Trescal · Milwaukee, WI](https://calibrationservicecompanies.com/trescal-milwaukee-wi-1078-01/)
*   [Trescal · Providence Forge, VA](https://calibrationservicecompanies.com/trescal-providence-forge-va-1486-02/)
*   [Trescal · San Jose, CA](https://calibrationservicecompanies.com/trescal-san-jose-ca-1797-01/)
*   [usCalibration · Irvine, CA](https://calibrationservicecompanies.com/uscalibration-irvine-ca-2092-01/)

Send your instrument model, quantity, test points, uncertainty requirement and due date. Include the worksite ZIP code for onsite service.

## Request calibration quotes

Write it once. Calibration Service Companies passes it to matching labs, and their replies come straight to your inbox.

Done. Calibration Service Companies is routing your request to the right labs.

Calibration Service Companies didn't receive your request. Check your email address and send it again, or email [hello@calibrationservicecompanies.com](mailto:hello@calibrationservicecompanies.com).

## Questions buyers ask

Can I use the printed CMC as my onsite uncertainty?

Use the uncertainty quoted for your site conditions. Transport, ambient conditions and the instrument’s behavior can contribute additional uncertainty. Open the field-service footnote in the scope. [Source](https://www.pjlabs.com/downloads/PL-4-Rev1-8.pdf)

What should I send for a temperature probe?

Send the probe type, connector, usable immersion depth, test temperatures and requested uncertainty. Say whether the readout is included.

How do I plan chamber mapping?

Specify the chamber range, loaded or unloaded condition, sensor positions, stabilization time and required sampling period.

```json
{"@context":"https://schema.org","@graph":[{"@type":"ItemList","@id":"https://calibrationservicecompanies.com/#list","name":"Onsite temperature calibration","numberOfItems":25,"itemListOrder":"https://schema.org/ItemListUnordered","itemListElement":[{"@type":"ListItem","position":1,"name":"Applied Technical Services · Bartlett, TN","url":"https://calibrationservicecompanies.com/applied-technical-services-bartlett-tn-1888-05/"},{"@type":"ListItem","position":2,"name":"Applied Technical Services · Greer, SC","url":"https://calibrationservicecompanies.com/applied-technical-services-greer-sc-1888-09/"},{"@type":"ListItem","position":3,"name":"Applied Technical Services · Marietta, GA","url":"https://calibrationservicecompanies.com/applied-technical-services-marietta-ga-1888-03/"},{"@type":"ListItem","position":4,"name":"Applied Technical Services · Sacramento, CA","url":"https://calibrationservicecompanies.com/applied-technical-services-sacramento-ca-7337-01/"},{"@type":"ListItem","position":5,"name":"Applied Technical Services · Tempe, AZ","url":"https://calibrationservicecompanies.com/applied-technical-services-tempe-az-1888-08/"},{"@type":"ListItem","position":6,"name":"Calibration Solutions · Pflugerville, TX","url":"https://calibrationservicecompanies.com/calibration-solutions-pflugerville-tx-3752-01/"},{"@type":"ListItem","position":7,"name":"Grand Rapids Metrology · Grand Rapids, MI","url":"https://calibrationservicecompanies.com/grand-rapids-metrology-grand-rapids-mi-1489-01/"},{"@type":"ListItem","position":8,"name":"JJ Calibrations · Portland, OR","url":"https://calibrationservicecompanies.com/jj-calibrations-portland-or-723-01/"},{"@type":"ListItem","position":9,"name":"National Calibration · Albuquerque, NM","url":"https://calibrationservicecompanies.com/national-calibration-albuquerque-nm-1892-02/"},{"@type":"ListItem","position":10,"name":"National Calibration · Scottsdale, AZ","url":"https://calibrationservicecompanies.com/national-calibration-scottsdale-az-1892-01/"},{"@type":"ListItem","position":11,"name":"Northstar Calibration · Owatonna, MN","url":"https://calibrationservicecompanies.com/northstar-calibration-owatonna-mn-462-02/"},{"@type":"ListItem","position":12,"name":"PharmaMatrix, LLC dba Applied Calibration Services · Wilson, NC","url":"https://calibrationservicecompanies.com/pharmamatrix-llc-dba-applied-calibration-services-wilson-nc-3374-01/"},{"@type":"ListItem","position":13,"name":"Quality Calibration Service · New Berlin, WI","url":"https://calibrationservicecompanies.com/quality-calibration-service-new-berlin-wi-462-01/"},{"@type":"ListItem","position":14,"name":"SIMCO · Allentown, PA","url":"https://calibrationservicecompanies.com/simco-allentown-pa-1395-09/"},{"@type":"ListItem","position":15,"name":"SIMCO · Bloomington, MN","url":"https://calibrationservicecompanies.com/simco-bloomington-mn-1395-14/"},{"@type":"ListItem","position":16,"name":"SIMCO · Panorama City, CA","url":"https://calibrationservicecompanies.com/simco-panorama-city-ca-1395-05/"},{"@type":"ListItem","position":17,"name":"SIMCO · Santa Clara, CA","url":"https://calibrationservicecompanies.com/simco-santa-clara-ca-1395-17/"},{"@type":"ListItem","position":18,"name":"SIMCO · Springboro, OH","url":"https://calibrationservicecompanies.com/simco-springboro-oh-1395-02/"},{"@type":"ListItem","position":19,"name":"Trescal · Arlington Heights, IL","url":"https://calibrationservicecompanies.com/trescal-arlington-heights-il-1022-03/"},{"@type":"ListItem","position":20,"name":"Trescal · Cornelius, NC","url":"https://calibrationservicecompanies.com/trescal-cornelius-nc-1877-01/"},{"@type":"ListItem","position":21,"name":"Trescal · Lansdale, PA","url":"https://calibrationservicecompanies.com/trescal-lansdale-pa-2551-01/"},{"@type":"ListItem","position":22,"name":"Trescal · Milwaukee, WI","url":"https://calibrationservicecompanies.com/trescal-milwaukee-wi-1078-01/"},{"@type":"ListItem","position":23,"name":"Trescal · Providence Forge, VA","url":"https://calibrationservicecompanies.com/trescal-providence-forge-va-1486-02/"},{"@type":"ListItem","position":24,"name":"Trescal · San Jose, CA","url":"https://calibrationservicecompanies.com/trescal-san-jose-ca-1797-01/"},{"@type":"ListItem","position":25,"name":"usCalibration · Irvine, CA","url":"https://calibrationservicecompanies.com/uscalibration-irvine-ca-2092-01/"}]},{"@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Lab register","item":"https://calibrationservicecompanies.com/"},{"@type":"ListItem","position":2,"name":"Onsite temperature calibration","item":"https://calibrationservicecompanies.com/onsite-temperature-calibration/"}]}]}
{"@context":"https://schema.org","@type":"FAQPage","mainEntity":[{"@type":"Question","name":"Can I use the printed CMC as my onsite uncertainty?","acceptedAnswer":{"@type":"Answer","text":"Use the uncertainty quoted for your site conditions. Transport, ambient conditions and the instrument’s behavior can contribute additional uncertainty. Open the field-service footnote in the scope."}},{"@type":"Question","name":"What should I send for a temperature probe?","acceptedAnswer":{"@type":"Answer","text":"Send the probe type, connector, usable immersion depth, test temperatures and requested uncertainty. Say whether the readout is included."}},{"@type":"Question","name":"How do I plan chamber mapping?","acceptedAnswer":{"@type":"Answer","text":"Specify the chamber range, loaded or unloaded condition, sensor positions, stabilization time and required sampling period."}}]}
```
